Annex 11

Annex 11 is the EU GMP annex on computerized systems, part of EudraLex Volume 4. It sets requirements for GMP-regulated systems, from risk management to electronic signatures.

Check the certifications and documentation behind Annex 11 compliance.

What is Annex 11?

Annex 11's full title is "Annex 11: Computerised Systems", also known as EU Annex 11 or EU GMP Annex 11. The European Commission published it under Article 47 of Directive 2001/83/EC and Article 51 of Directive 2001/82/EC. It applies to computerized systems used in Good Manufacturing Practice (GMP) regulated activities, covering risk management, suppliers, validation, data, audit trails, security, and electronic signatures. The current text is revision 1, in effect since 30 June 2011.

Data managers often compare Annex 11 with two other texts. Here's how the three compare:

Data managers often answer Annex 11 and Part 11 questions together. Both texts cover audit trails, electronic signatures, and access, but word the requirements differently.

  • Audit trails. Annex 11 section 9 expects a system-generated audit trail for GMP-relevant changes and deletions, based on a risk assessment. The team should document the reason for each change and review the trail regularly. 21 CFR 11.10(e) asks for secure, computer-generated, time-stamped audit trails, with record changes that don't obscure previously recorded information.
  • Electronic signatures. Annex 11 section 14 expects electronic signatures to have the same impact as hand-written signatures within the company, to be permanently linked to their record, and to include the time and date they were applied. 21 CFR 11.50 and 11.70 ask that a signed record show the signer's printed name, the date and time, and the meaning of the signature, and that the system link signatures to their records.
  • Access. Annex 11 section 12 asks for controls that restrict access to authorized persons, and requires a record whenever someone creates, changes, or cancels an access authorization. 21 CFR 11.10(d) asks that only authorized individuals have access to the system.

Why Annex 11 matters for CROs and sponsors

For a CRO

Annex 11 is relevant on studies with EU sites or EU submissions, because vendors, including EDC vendors, list it among the standards they support. It also governs mid-study changes: section 10 requires that any change to a computerized system follow a defined, controlled procedure. For changes to a study build, read Annex 11 alongside the EMA guideline on computerized systems and electronic data in clinical trials.

For a sponsor

Annex 11 shows up in questionnaires and audits even when the trial isn't a manufacturing activity, so it helps to understand its scope, what a vendor's support for it actually covers, and which version of the text currently applies.

  • Scope. Annex 11 applies to GMP regulated activities. The EMA guideline, adopted by the Good Clinical Practice (GCP) Inspectors Working Group on 7 March 2023 and in effect six months after publication, applies to clinical trials.
  • Supplier duties. Vendor support doesn't make a study meet Annex 11 on its own. Section 3 expects regulated users to review supplier documentation.
  • Revision status. The European Commission ran a stakeholders' consultation on Chapter 4, Annex 11 and a new Annex 22, from 7 July 2025 to 7 October 2025. It hasn't published an adoption or effective date for the revised text, so revision 1 still applies.

Getting started with Annex 11

To work with Annex 11, a CRO or sponsor team should:

  1. Confirm whether the study has EU sites, EU submissions, or GMP activities in scope.

  2. Read Annex 11 alongside the EMA guideline on computerized systems and electronic data in clinical trials.

  3. Map the EDC and other systems to the Annex 11 sections that apply.

  4. Put formal agreements in place with suppliers and review their documentation (section 3).

  5. Track the European Commission's revision of Annex 11 and update procedures once it adopts a new text.

Woman in a modern office sitting at a desk and working on her laptop

Annex 11 with Viedoc

Viedoc's certifications and documentation support Annex 11 compliance, but they don't replace it. Section 3 still expects regulated users to have a formal agreement with their supplier and to review the supplier's documentation themselves.

Support for EU and US rules

Viedoc's platform supports 21 CFR Part 11, ICH GCP, EU Annex 11, GDPR, HIPAA, GAMP 5, and CDISC, plus Japanese PMDA, ER/ES, and APPI requirements.

Supplier documentation to review

Each Viedoc release comes with validation documentation, including a Validation Summary Report, User Requirement Specification, Traceability Matrix, Release Certificate, and Impact Assessment.

Inspection readiness built in

Viedoc customers can download the complete Viedoc Inspection Readiness Packet (VIRP) from within Viedoc Admin, with a public overview available on Viedoc's website.

Independent security assurance

Viedoc is certified to ISO 27001:2022 with all Annex A controls included, and has a SOC 2 Type 2 report issued by an authorized third-party auditor.

Woman sitting at her desk in front of a large computer monitor using a piece of software

Key takeaways: Annex 11

  • Annex 11 is the EU GMP annex on computerized systems, part of EudraLex Volume 4.

  • It overlaps with 21 CFR Part 11 on validation, audit trails, and electronic signatures, but the two are separate texts: Annex 11 applies to GMP activities, not clinical trials specifically.

  • Vendor support alone doesn't make a study meet Annex 11; section 3 still expects a formal agreement and a review of the supplier's documentation.

  • For a CRO, Annex 11 affects vendor questionnaires and change control; for a sponsor, it affects supplier agreements and audit readiness.

Frequently asked questions about Annex 11

Related terms