21 CFR Part 11

21 CFR Part 11 is the US FDA regulation that sets the criteria under which the agency considers electronic records and electronic signatures trustworthy, reliable, and generally equivalent to paper records and handwritten signatures (section 11.1(a)). In clinical research it applies to electronic records kept in systems such as EDC, and covers validation, audit trails, access controls, and signature controls.

See how Viedoc supports 21 CFR Part 11 requirements.

What is 21 CFR Part 11?

21 CFR Part 11 sits in Title 21 of the US Code of Federal Regulations, covering electronic records and electronic signatures. The Food and Drug Administration (FDA) published it in the Federal Register at 62 FR 13464 on 20 March 1997, and it took effect that August.

It's not computer system validation, which is just one of the controls it lists, and it's not a product certificate: compliance depends on how an organization runs its systems, not just the software it uses.

Section 11.3(b) defines the terms the rule uses, including closed system, electronic record, electronic signature, and open system. Subpart B covers electronic records (sections 11.10, 11.30, 11.50, and 11.70). Subpart C covers electronic signatures (sections 11.100, 11.200, and 11.300).

The table shows the parts a data manager meets most often in an electronic data capture (EDC) system.

Electronic signatures under 21 CFR Part 11

Part 11 covers signatures in two places. Sections 11.50 and 11.70 set how a signature shows on a record and stays linked to it, and Subpart C sets the rules for the signature itself.

  • What a signed record shows (11.50). Each signed electronic record must show the printed name of the signer, the date and time of signing, and the meaning of the signature, such as review, approval, responsibility, or authorship. These items must also appear in any human-readable form of the record, such as a screen display or a printout.
  • Signatures stay with their records (11.70). The organization must link electronic and handwritten signatures to their records, so no one can excise, copy, or otherwise transfer them to falsify a record by ordinary means.
  • One person, one signature (11.100). Each electronic signature must be unique to one individual, and no one may reuse or reassign it. The organization must verify that person's identity before assigning it. It must also certify to the FDA, in a document signed by hand, that its electronic signatures carry the same legal weight as handwritten ones.
  • Two components (11.200). Signatures not based on biometrics need at least two distinct identification components, such as an identification code and a password. In one continuous period of controlled system access, the first signing uses all components, and later signings use at least one. Signings outside that period use all components every time. Biometric signatures must work so only their genuine owner can use them.
  • Identification code and password controls (11.300). The controls include keeping each combined code and password unique, checking or revising issued codes and passwords periodically, deauthorizing lost or compromised tokens and cards, and detecting and reporting attempts at unauthorized use.

In the EU, Annex 11 section 14 allows electronic signatures on records. It expects electronic signatures to have the same impact as handwritten signatures within the boundaries of the company, to link permanently to their record, and to carry the date and time of signing.

For a data manager, these rules shape the signature set-up in the study build: which roles sign which forms, and what each signature means. Identity checks and password procedures sit with the organization, so quality assurance (QA) and IT own that part.

Why 21 CFR Part 11 matters for CROs and sponsors

For a CRO

Part 11 questions arrive with every sponsor's vendor qualification and audit, and the data management team answers many of them. Sections 11.10(i) and (j) cover people and written policies, so the CRO's own training records and procedures are part of the answer, not only the system.

For a sponsor

21 CFR Part 11 decides whether an FDA inspector can trust the electronic records behind a submission. The questions come up during vendor qualification, and a weak answer there can slow it down. In October 2024, the FDA issued final guidance titled "Electronic Systems, Electronic Records, and Electronic Signatures in Clinical Investigations: Questions and Answers", alongside the September 2003 scope and application guidance.

For both, Part 11 applies to records and to how an organization runs its systems, so a vendor can support the work but can't finish it alone. The organization should also check studies with EU sites against Annex 11.

Getting started with 21 CFR Part 11

Getting started with 21 CFR Part 11 means mapping each system that holds trial records to the controls in section 11.10, then splitting the work between vendor, CRO, and sponsor.

  1. List every system that will hold electronic records for the study, starting with the EDC.

  2. Map each system to the controls in the table above and note who owns each one.

  3. Ask each vendor for its validation and inspection evidence, such as an inspection readiness packet.

  4. Validate your own study configuration and write procedures for access, signatures, and audit trail review.

  5. Read the FDA's 2024 clinical investigations guidance and its 2003 scope guidance with your QA lead.

Woman in a modern office sitting at a desk and working on her laptop

21 CFR Part 11 with Viedoc

Support for the rules you work under

Viedoc supports 21 CFR Part 11, the EU's Annex 11, and the International Council for Harmonisation's Good Clinical Practice guideline (ICH GCP). It also meets GDPR and HIPAA, follows the GAMP 5 (Good Automated Manufacturing Practice) validation framework, and uses the Clinical Data Interchange Standards Consortium (CDISC) data standards. In Japan, it supports the Pharmaceuticals and Medical Devices Agency's (PMDA) electronic records and signatures (ER/ES) requirements and the Act on the Protection of Personal Information (APPI).

Validation evidence for each release

Each release comes with validation documentation: a Validation Summary Report, User Requirement Specification, Traceability Matrix, Release Certificate, and Impact Assessment.

Inspection readiness at no extra cost

Viedoc customers download the complete Viedoc Inspection Readiness Packet (VIRP) from Viedoc Admin, and a public overview is available on Viedoc's website.

Audit trails among the security controls

Viedoc's security controls include encryption, multi-factor authentication, audit trails, vulnerability scanning, and continuous penetration testing.

Woman sitting at her desk in front of a large computer monitor using a piece of software

Key takeaways: 21 CFR Part 11

  • 21 CFR Part 11 is the FDA regulation on electronic records and electronic signatures, effective since August 1997.

  • In clinical trials it applies to records held in systems such as EDC.
  • Section 11.10 lists the controls for closed systems, including validation, access limits, audit trails, authority checks, training of the people who use the systems, and written policies.
  • A signed record must show the signer's printed name, the date and time, and the meaning of the signature, and each signature must be unique to one person.
  • Part 11 applies to records and to how an organization runs its systems, so the vendor, the CRO, and the sponsor each have work to do.

Frequently asked questions about 21 CFR Part 11

Related terms